Load Banks for Rent

United Rentals has an extensive lineup of load banks for rent to provide reliable electrical testing solutions. From resistive and reactive to capacitive and more, we carry a variety of load banks for all your power testing needs.

For our full list of load banks for rent, view the items below. For more information about load banks, visit our resource section.

rack mount load bank
Cat Class Code
241-0050

17-20 kW Rack Mounted Load Bank

  • 17-20 kW capacity
  • Designed for mounting on a 19" server rack
  • Lightweight 43-45 lb. design for easy handling
  • Variable airflow speed control
  • Uses: Ideal for simulating server loads for your data center
100 kW Networkable Resistive Load Bank
Cat Class Code
241-0060

100 kW Resistive Load Bank, Networkable

  • 100 kW capacity
  • 240/480V
  • 50 or 60 hertz output frequency depending on model
  • Networkable with up to 128 load banks
  • Uses: Ideal for testing a broad range of power sources like generators, turbines, UPS systems and more
125 kW Networkable Resistive Load Bank
Cat Class Code
241-0125

125 kW Resistive Load Bank, Networkable

  • 125 kW capacity
  • 240/480V, 208V, 415V
  • Rated for continuous operation
  • Networkable with up to 128 load banks
  • Uses: Ideal for testing a broad range of power sources like generators, turbines, UPS systems and more
Gray Asco Resistive Load Bank
Cat Class Code
241-0265

265 kW Resistive Load Bank, Networkable

  • 265 kW capacity
  • 480/240/208V
  • Rated for continuous operation
  • Networkable with up to 128 load banks
  • Uses: Ideal for testing a broad range of power sources like generators, turbines, UPS systems and more
blue 200kW Resistive Load Bank
Cat Class Code
241-0350

400 kW Resistive Load Bank, Networkable

  • 400 kW capacity
  • 240/480V, 480V, 600V
  • Rated for continuous operation
  • Networkable with up to 128 load banks
  • Uses: Ideal for testing a broad range of power sources like generators, turbines, UPS systems and more
Blue Resistive Portable Load Bank
Cat Class Code
241-0600

600 kW Resistive Load Bank, Networkable

  • 600 kW capacity
  • 240/480V, 208V
  • Rated for continuous operation
  • Networkable
  • Uses: Ideal for testing a wide range of power sources for medium-duty commercial applications
Blue and gray Networkable Resistive Load Bank
Cat Class Code
241-0825

1,000 kW Resistive Load Bank, Networkable

  • 600-1,000 kW capacity
  • 240/480V, 600V
  • Rated for continuous operation
  • Networkable
  • Uses: Ideal for testing a broad range of power sources or to use with up to 128 load banks on a network
1,250 kW Networkable Resistive Load Bank
Cat Class Code
241-0915

1,250 kW Towable Resistive Load Bank, Networkable

  • 1,250 kW capacity
  • 480V, 240V, 208V
  • Rated for continuous operation
  • Networkable with up to 128 load banks
  • Uses: Ideal for testing a broad range of power sources like generators, turbines, UPS systems and more
Blue and gray Load Bank
Cat Class Code
241-0925

2,500 kW Resistive Load Bank, Networkable

  • 2,500 kW capacity
  • 240/480V, 480V
  • Rated for continuous operation
  • Networkable with up to 32 load banks
  • Uses: Ideal for testing a broad range of power sources like generators, turbines, UPS systems and more
3,000 kW Networkable Resistive Load Bank
Cat Class Code
241-1150

3,000 kW Towable Resistive Load Bank, Networkable

  • 3,000 kW capacity
  • 480V
  • Rated for continuous operation
  • Networkable with up to 32 load banks
  • 1kW load stUses: Ideal for testing a broad range of power sources like generators, turbines, UPS systems and moreep resolution
2000 kVAR Capacitive Load Bank
Cat Class Code
241-1425

2,000 KVAR Capacitive Load Bank

  • 2,000 KVAR capacity
  • 480V
  • Rated for continuous operation
  • Three-phase
  • Uses: Ideal for adjusting power factors in industrial and commercial applications
Cat Class Code
241-1660

3,000 kVAR Reactive Load Bank

  • 3,000 kVAR capacity
  • 3-phase, 415V
  • Rated for continuous operation
  • Features automatic load control
  • Uses: Ideal for testing the loads of your power sources up to 3,000 kVAR for commercial or industrial work
1.8 MVA Resistive/Reactive Load Bank
Cat Class Code
241-1900

1,800 kVA Resistive/Reactive Load Bank, Networkable

  • 1,800 kVA capacity
  • 480V
  • Rated for continuous operation
  • Features camlock connectors
  • Uses: Ideal for testing power generation and distribution equipment with up to 16 load banks on a network
Gray Asco Resistive/Reactive Load Bank
Cat Class Code
241-2000

3,300 kVA Resistive/Reactive Load Bank, Networkable

  • 3,300 kVA capacity
  • 480V
  • Rated for continuous operation
  • 19,000-20,000 lbs. depending on model
  • 2kW load step resolution
  • Uses: Ideal for testing power generation and distribution equipment with up to 16 load banks on a network
Gray Asco Resistive/Reactive Load Bank
Cat Class Code
241-2010

3,700 kVA Resistive/Reactive Load Bank, Networkable

  • 3,700 kVA capacity
  • 380-480V
  • Rated for continuous operation
  • Features camlock connectors
  • 2kW load step resolution
  • Uses: Ideal for testing power generation and distribution equipment with up to 16 load banks on a network
6.25 MVA Resistive/Reactive Load Bank
Cat Class Code
241-2100

6,250 kVA Resistive/Reactive Load Bank, Networkable

  • 6,250 kVA capacity
  • 380-480V
  • Rated for continuous operation
  • 36,000-38,000 lbs. depending on model
  • Uses: Ideal for testing power generation and distribution equipment with up to 16 load banks on a network
Resources

FAQs About Load Banks

Load banks test, optimize and maintain a variety of electrical power sources like generators and uninterruptible power supplies (UPS) to ensure optimal performance if ever needed. Rent load banks of all kinds, from compact, portable models ideal for testing smaller, jobsite UPS to large, networkable units for commercial and industrial uses. Choose between resistive, capacitive, reactive and resistive/reactive load banks to find the perfect load bank rental for the job. We carry top manufacturers like Avtron, ASCO, Trystar, LBD and more to ensure you get the highest quality equipment for your next project. Contact a United Rentals expert to ensure you find the right load bank for rent to help you get your job done. Check out our Project Uptime article, Faster Load Bank Testing for Data Center Commissioning for more information.

For more information about this equipment, visit the FAQ section below.

FAQs
How do I determine the right load bank capacity for my application?

A load bank with a capacity equal to or greater than the rated output of the power source you are testing is recommended.

What are the common types of load banks?

The most common types of load banks are resistive load banks, inductive load banks, capacitive load banks and resistive/reactive load banks.

Do I need a load bank for a generator?

A good rule of thumb is that if a generator has not been used at more than 30% of its rated load, you should have it load tested before use. Load testing the generator ensures it will produce power as required and in emergencies.