Diesel Generator - 18 kVA Stage V

Diesel Generator 18 kVA
Diesel Generator 18 kVA

IDEAL USAGE

Projects that require efficient and reliable low emission temporary power supply of 18 kVA including an integrated Distribution Panel
 

APPLICATIONS
 

  • Temporary Power supply for projects for which connecting to an electricity grid isn’t available, such as temporary accommodations and construction or other remote sites.
  • Backup or bypass power supply during (maintenance) works in order to keep (industrial) equipment operational
  • Additional power for (seasonal) increases in demand
  • Standalone power supply for secondary processes

 

BENEFITS

  • Auto Start Controller
  • Remote Monitoring (Livelink for Power)
  • Reduced sound pressure due to Residential Silencer
  • Integrated distribution panel
  • Outstanding reliability and high performance
  • Easy integration with other United Rentals equipment
  • Stage V Complaint
RESOURCES

Diesel Generator 18 kVA Stage V

PERFORMANCE

Power Factor:

3 phase: 0.8
1 Phase: 1

Fuel Consumption:

100% Load Prime       50 Hz      4.45 L/h
75% Load Prime                        3.29 L/h
50% Load Prime                        2.24 L/h
100% Load Standby                  4.93 L/h

Fuel System:

Diesel Specification                   EN590
Standard Capacity Fuel Tank    100 L

Typical Sound Pressure:

dBa @ 7 50 Hz 63 dBa

WEIGHTS AND MEASURES

Wet Weight:

1010 Kg

Dimensions:

1423 mm x 835 mm x 1948 mm (H x W x L)

ENGINE AND ALTERNATOR

Engine:

                                            1500 RPM 
New Output Rating (PRP)        17 kW    
Net Output Rating (Standby)    19 kW    

Manufacturer and Model: JCB by Kohler KDI M 1903 E5
Fuel: Diesel
Injection: Direct
Aspiration: Naturally Aspirated
Cylinders:3
Bore and Stroke:88 x 102 mm
Displacement: 1.86 L
Cooling: Water
Compression Ratio: 11.5 : 1
Engine Oil Specification: API CH4 SAE 10W40
Engine Oil Capacity: 8.90 L
Coolant Capacity: 6.80 L
Governer: Mechanical
Air Filter: Paper Element
Engine Oil Consumption: 0.1% of fuel consumed 
Exhaust Emission After Treatment: None
Emission Standard: Stage V

Alternator ECP28 - 2L/4:

Poles: 4
Winding Connections: Star
Insulation: Class H
Enclosure: IP23
Exciter System: Self Regulating brushless
Voltage Regulator: AVR 
Steady State Voltage Regulation:  +/- 1%
Bearing: Single bearing sealed
Coupling: Flexible disc
Cooling: Direct drive centrifugal fan
Coating: Total Protection +
Heater: Anti-condensation

Starting System:

Battery Capacity: 110 Ah
Number of Batteries: 1
Auxillery Voltage: 12 V

Air System:

Intake Air Flow 100% Standby: 50 Hz 82 m³/h 
Radiator Cooling Airflow: 0.47 m³/h

Exhaust System:

Maximum temperature:                     50 Hz    540 °C
Exhaust Gas Flow 100% Standby:                 2.01 m³/min
Maximum Allowed Back Pressure:                 5.00 kPa
Exhaust Discharge Size:                                45 mm
 

DATA SHEET