Diesel Generator - 40 kVA Stage V
IDEAL USAGE
Projects that require efficient and reliable low emission temporary power supply of 40 kVA including an integrated Distribution Panel
APPLICATIONS
- Temporary Power supply for projects for which connecting to an electricity grid isn’t available, such as temporary accommodations and construction or other remote sites.
- Backup or bypass power supply during (maintenance) works in order to keep (industrial) equipment operational
- Additional power for (seasonal) increases in demand
- Standalone power supply for secondary processes
BENEFITS
- Auto Start Controller
- Remote Monitoring (Livelink for Power)
- Reduced sound pressure due to Residential Silencer
- Integrated distribution panel
- Outstanding reliability and high performance
- Easy integration with other United Rentals equipment
- Stage V Complaint
Diesel Generator 40 kVA Stage V
Power Factor:
3 phase: 0.8
1 Phase: 1
Fuel Consumption:
100% Load Prime 50 Hz 9.56 L/h
75% Load Prime 7.44 L/h
50% Load Prime 5.43L/h
100% Load Standby 10.32L/h
Fuel System:
Diesel Specification EN590 & EN15940
Standard Capacity Fuel Tank 226 L
Typical Sound Pressure:
dBa @ 7 50 Hz 67 dBa
Wet Weight:
1540 Kg
Dimensions:
1574 mm x 1050 mm x 2265 mm (H x W x L)
Engine:
New Output Rating (PRP) 42.4 kW
Net Output Rating (Standby) 47.1 kW
Manufacturer and Model: JCB by Kohler KDI 2504 TCR
Engine Speed: 1500 RPM
Fuel: Diesel
Injection: Direct
Aspiration: Turbo Charged
Cylinders: 4
Bore and Stroke:88 x 102 mm
Displacement: 2.482 L
Cooling: Water
Compression Ratio: 17.4 : 1
Engine Oil Specification: API CJ4 - ACEA E9, E7, E6
Engine Oil Capacity: 11.20 L
Coolant Capacity: 4.20 L
Governer: Electronic
Air Filter: Paper Element
Engine Oil Consumption: <0.1% of fuel consumed
Exhaust Emission After Treatment: DOC / DPF
Emission Standard: Stage V
Alternator ECP32 - 2S4C:
Poles: 4
Winding Connections: Star
Insulation: Class H
Enclosure: IP23
Exciter System: Self Regulating brushless
Voltage Regulator: Digital AVR
Steady State Voltage Regulation: +/- 1%
Bearing: Single bearing sealed
Coupling: Flexible disc
Cooling: Direct drive centrifugal blower fan
Coating: Total Protection +
Heater: Anti-condensation
Starting System:
Battery Capacity: 110 Ah
Number of Batteries: 1
Auxillery Voltage: 12 V
Air System:
Intake Air Flow 100% Standby: 168 m³/h
Radiator Cooling Airflow: 2 m³/s
Exhaust System:
Maximum temperature: 520 °C
Maximum temperature - Regeneration: 600 °C
Exhaust Gas Flow 100% Standby: 16.67 m³/min
Maximum Allowed Back Pressure: 11 kPa
Exhaust Discharge Size: 60.5 mm