Diesel Generator 60 kVA

G60RS -UR.png
G60RS -UR.png

IDEAL USAGE

Projects that require efficient and reliable temporary power, including industrial locations
 

APPLICATIONS
 

  • Powering locations where permanent electricity supply is not available -such as temporary accommodation, construction or other remote sites
  • Replacing utility power supply to industrial equipment - motors, pumps, conveyors and other equipment
  • Additional power for seasonal increases in demand such as manufacturing, distribution and strorage
     

BENEFITS

  • Telemetry and multiple generator synchronisation
  • Fuel efficient, proven reliability
  • Robust design
RESOURCES

Diesel Generator 60 kVA

PERFORMANCE

Power Factor:

3 phase: 0.8
1 Phase: 1

Fuel Consumption:

100% Load Prime       50 Hz     15.90 L/h
75% Load Prime                       12.60 L/h
50% Load Prime                        8.70 L/h
100% Load Standby                 17.30 L/h

100% Load Prime       60 Hz    17.60 L/h
75% Load Prime                       13.20 L/h
50% Load Prime                       10.10 L/h
100% Load Standby                 19.10 L/h

Fuel System:

Diesel Specification                   EN590
Standard Capacity Fuel Tank    280 L

Typical Sound Pressure:

dBa @ 7 50 Hz 69 dBa

 

WEIGHTS AND MEASURES

Weight:

2045 Kg
*Standard build with all fluids except fuel

Dimensions:

1912 mm x 1200 mm x 3334 mm (H x W x L)

Shipping Volume:

Sea Ready: 7.70 m³

ENGINE AND ALTERNATOR

Engine:

                                            1500 RPM 1800 RPM
New Output Rating (PRP)        54 kW    54 kW
Net Output Rating (Standby)    56 kW    56 kW

Manufacturer and Model: JCB 448 G - TCA 60
Fuel: Diesel
Injection: Direct
Aspiration: Turbo Charged
Cylinders:4
Bore and Stroke:103 x 135 mm
Displacement: 4.77 L
Cooling: Water
Compression Ratio: 18 : 1
Engine Oil Specification: API CH4 SAE 10W40
Engine Oil Capacity: 15:00 L
Coolant Capacity: 16.00 L
Governer: Mechanical
Air Filter: Paper Element
Engine Oil Consumption: 100% 0.1% of fuel consumed Load
Exhaust Emission After Treatment: None
Emission Standard: Stage IIIA Transition

Alternator ECP32-2M4B:

Poles: 4
Winding Connections: Star
Insulation: Class H
Encloser: IP23
Exciter System: Self Regulating brushless
Voltage Regulator: AVR 
Steady State Votlage Regulator:  +/- 1%
Bearing: Single bearing sealed
Coupling: Flexible doc
Cooling: Direct drive centrifugal fan

Starting System:

Battery Capacity: 120 Ah
Number of Batteries: 1
Auxillery Voltage: 12 V

Air System:

Intake Air Flow 100% Standby: 50 Hz 301 m³/h 
Radiator Cooling Airflow: 3.3 m³/h

Exhaust System:

Maximum temperature:                     50 Hz    511 °C
Exhaust Gas Flow 100% Standby:                 13.43 m³/min
Maximum Allowed Back Pressure:                 9.00 kPa
Exhaust Discharge Size:                                80 mm
 

 

DATA SHEET